Daikin XL 9.0kW FTXV90WVMA Inverter Split System supply and install
by daikin
$3,100.00
Powerful airflow delivery, large capacity models designed for large open plan living. Available in two ranges, XL and the more energy efficient XL Premium.
Specification :
Model | Indoor Unit | FTXV90WVMA | |
Outdoor Unit | RXV90WVMA | ||
Cooling | Heating | ||
Capacity (Rated) (Min. — Max.) / Half / Low Temperature |
kW | 9.000 (2.000 – 11.200) / 4.500 / — | 10.300 (1.900 – 12.000) / 5.150 / 8.700 |
Btu/h | 30,700 (6,800 – 38,200) / 15,400 / — | 35,100 (6,500 – 40,900) / 17,600 / 29,700 | |
kcal/h | 7,740 (1,720 – 9,630) / 3,870 / — | 8,860 (1,630 – 10,320) / 4,430 / 7,480 | |
Moisture Removal | L/h | 5.7 | — |
Running Current (Rated) | A | 12.5- 12.0 – 11.5/ 12.5- 12.0 | 14.9 – 14.3 – 13.7 / 14.9 – 14.3 |
Power Consumption (Rated) (Min. — Max.) / Half / Low Temperature |
w | 2,650 (410 – 4,260) /930 / — | 3,150 (410 – 4,160) / 1,150/ 3,600 |
Power Factor (Rated) | % | 96.4 – 96.0 – 96.0 / 96.4 – 96.0 | 96.1 – 95.8 – 95.8 / 96.1 – 95.8 |
COP (Rated) | W/W | 3.4 | 3.27 |
AEER / ACOP | 3.376 | 3.253 | |
Liquid (mm) | 6.4 | 6.4 | |
Piping Connections | Gas (mm) | 15.9 | 15.9 |
Drain (mm) | 16 | 16 | |
Heat Insulation | Both Liquid and Gas Pipes | Both Liquid and Gas Pipes | |
Max. Interunit Piping Length | m | 30 | 30 |
Max. Interunit Height Difference | m | 20 | 20 |
Chargeless | m | 10 | 10 |
Amount of Additional Charge of Refrigerant | g/m | 20 | 20 |
Indoor Unit | FTXV90WVMA | ||
Front Panel Colour (Munsell No.) | White (N9.5) | ||
Airflow Rate | H (m3/min (cfm)) | 26.4 (932) | 25.5 (900) |
M (m3/min (cfm)) | 21.9 (773) | 18.3 (646) | |
L (m3/min (cfm)) | 17.6 (621) | 14.0 (494) | |
SL (m3/min (cfm)) | 15.1 (533) | 12.4 (438) | |
Type | Cross Flow Fan | ||
Fan | Motor Output (w) | 103 | |
Speed (Steps) | 5 Steps, Quiet, Auto | ||
Air Direction Control | Right, Left, Horizontal, Downwards | ||
Air Filter | Removable, Washable, Mildew Proof | ||
Running Current (Rated) | A | 0.89- 0.85 – 0.81 / 0.89- 0.85 | 0.83- 0.79 – 0.76/0.83 – 0 79 |
Power Consumption (Rated) | w | 101 | 94 |
Power Factor (Rated) | % | 51.6- 51.7 – 52.0/51.6 – 51.7 | 51.5-51.7 – 51.5/ 51.5 – 51 7 |
Temperature Control | Microcomputer Control | ||
Dimensions (H x W x D) | mm | 329 x 1,240 x 278 | |
Packaged Dimensions (H x W x D) | mm | 405 x 1,349 x 421 | |
Weight (Mass) | kg | 19 | |
Gross Weight (Gross Mass) | kg | 27 | |
Sound Pressure Level / H/ M / L / SL | dB(A) | 53 / 48 / 42 / 38 | 52 / 45 / 38 / 35 |
Sound Power Level | dB | 69 | 68 |
Outdoor Unit | RXV90WVMA | ||
Casing Colour | Ivory White | ||
Heat Exchanger | Fin / Spec. Tube | Waffle Fin / 7 Hi-XD Tube | |
Compressor | Type | Hermetically Sealed Swing Type | |
Model | 2YC71BXD | ||
Motor Output (w) | 2,400 | ||
Refrigerant Oil | Type | FW68DA | |
Charge (L) | 0.9000 | ||
Refrigerant | Type | R-32 | |
Charge (kg) | 2.13 | ||
Airflow Rate | H (m3/min (cfm)) | 70.5 (2,489) | 65.9 (2,327) |
SL (m3/min (cfm)) | 60.4 (2,133) | 51.3 (1,811) | |
Type | Propeller | ||
Fan | Motor Output (w) | 117 | |
Running Current (Rated) | A | 1 1.60 – 1 1.20 – 10.70/11.60 – 11.20 | 14.10 – 13.50 – 12.90 /14.10 – 13.50 |
Power Consumption (Rated) | w | 2,549 | 3,056 |
Power Factor (Rated) | % | 99.9 – 99.0 – 99.3 /99.9 – 99.0 | 98.5 – 98.4 – 98.7 /98.5 – 98.4 |
Starting Current | A | 14.9 | |
Dimensions (H x W x D) | mm | 990 x 940 x 320 | |
Packaged Dimensions (H x W x D) | mm | 1,114 x 1,003 x 396 | |
Weight (Mass) | kg | 77 | |
Gross Weight (Gross Mass) | kg | 87 | |
Sound Pressure Level | H/ SL – dB(A) | 54 / 51 | 55 / 51 |
Sound Power Level | H (dB) | 66 | 67 |
Drawing No. | 3D142725A |